| Braeburn 5200 24V MULTI STAGE AC POWERED DIGITAL 5/2 OR 7 DAY PROGRAMMABLE HEATPUMP THERMOSTAT WITH AUX. HEAT FOSSIL FUEL SWITCH, BATTERY BACK-UP 2H-2C 45-90F Features
• Universal 7 Day or 5-2 Day Programming
• Large Display with Bright Blue Backlight
• AC Powered with Battery Back-Up
• Non-Volatile Memory to Maintain User Settings
• Recirculating Fan Mode
• Residual Cooling Fan Delay
• Filter Check Monitor
• Adaptive Recovery Mode (ARM™)
• Adjustable 1st and 2nd Stage Temperature Differential
• Auxiliary Heat Fossil Fuel Switch
• ESD Guard™ Electronic Circuitry
• Compressor Short Cycle Protection
• Compressor Power Outage Protection
• AC Power Monitor
• Separate Heating and Cooling Set Point Program Times
and Temperatures
• Temporary Program Override for 4 Hours or Until
Next Set Point
• Programmable Extended Hold Mode
• Front Access Reset Button
• F° / C° Switch
• Gas / Electric Fan Switch
• Mounts to Vertical or Horizontal Box
• Easy Access Front Battery Door
• Separate O & B Terminals
• Multi-Colored LED Status Indicators
• Keypad Lockout
• Meets ENERGY STAR® and California Title 24 Guidelines Product Specifications
Dimensions: 4.63” x 5.00” x 1.25”
Electric Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
3 amp total maximum load (all terminals)
AC Power: 18-30 Volt AC
DC Back-Up Power: 3.0 Volts DC
(2 “AA” Alkaline batteries included)
Compatibility: Multi-stage heat pump systems with up
to two stages of heating and two
stages of cooling
Control Range: 45° to 90° F (7° to 32° C)
Display Range: 40° to 99° F (4° to 37° C)
Accuracy: +/- 1° F (+/- .5° C)
Temperature
Differential: 1st Stage - .5°, 1°, or 2° F (.25°, .5°, or 1° C)
2nd Stage - 2°, 3°, 4°, 5°, or 6° F
(1°, 1.5°, 2°, 2.5°, or 3° C)
Storage Temperature: 14° to 140° F (-10° to 60° C)
Operating Humidity: 5% to 95% Relative Humidity
Interchangeable
Sub-Base: Braeburn 3200 Non-Programmable
2 Heat / 2 Cool Heat Pump
Terminations: R, Y1, Y2, W2, E, G, O, B, L, C |