White Rodgers 1F95-1277 Universal Touchscreen
|
|
White Rodgers 1F95-1277 24V/MILLIVOLT 2 OR 3 WIRE UNIVERSAL SINGLE STAGE, MULTI-STAGE 2H-2C OR HEAT PUMP 3H-2C DUAL POWERED DIGITAL PROGRAMMABLE / NON-PROGRAMMABLE TOUCHSCREEN THERMOSTAT WITH AUTO CHANGE OVER & KEYPAD LOCKOUT 45-99F FEATURES • Large 12-square-inch touchscreen display – largest in the industry. • Extra-large touch keys for easy operation. • Universal Dual-Powered – choice of battery-powered or hardwired with battery back-up. • Meets ENERGY STAR ® specifications.• Meets California Building Code, Title 24. • Universal – choice of 7 day, 5/1/1 day programmable or non-programmable (installer selectable). • Audible feedback. • 1 F95-1277/1F97-1277 include these additional features: – Remote sensing indoor/outdoor. – Programmable fan. – Circulator fan cycling. – Automatic daylight savings option. – Dual-fuel heat pump control (1F95-1277). – Patented Cool Savings. – Enhanced security settings. – 3 wire zone valve. SPECIFICATIONS Electrical Rating Battery Power . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC Input-Hardwire . . . . . . . . . . . . . . . . . . . 20 to 30 VAC Terminal Load . . . . . . . . . . . . . . . . . . . 1 .5 A per terminal, 2.5 A maximum all terminals combined Setpoint Range . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C) Differential (Single Stage) . . . . . . . . . . Heat 0.6°F; Cool 1.2°F Differential (Multi-Stage) . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F Differential (Heat Pump) . . . . . . . . . . . Heat 1.2°F; Cool 1.5°F Operating Ambient . . . . . . . . . . . . . 32 to +105°F (0 to +41°C) Operating Humidity . . . . . . . . . . . . . . . 90% non-condensing max. Shipping Temperature Range . . . . . . . –4 to 150°F (–20 to 65°C) Dimensions . . . . . . . . . . . . . 4 9/16”H x 513/16”W x 13/16”D |
|
|
|
White Rodgers 1F95-1291 Universal Touchscreen with De-Humudifica
|
|
White-Rodgers 1F95-1291 24V/MILLIVOLT 2 OR 3
WIRE UNIVERSAL MULTI-STAGE 2H-2C OR
HEAT PUMP 4H-2C DUAL POWERED
DIGITAL PROGRAMMABLE /
NON-PROGRAMMABLE TOUCHSCREEN
THERMOSTAT WITH AUTO CHANGE OVER,
KEYPAD LOCKOUT,
DE-HUMIDIFICATION/HUMIDIFICATION
CONTROL 45-99F
Programming
Universal – installer selectable system
applications
Choice of 7 day, 5/1/1 day programmable or
non-programmable (installer selectable)
4 time and 4 temperature settings per program
(2 setbacks) heat and cool, or selectable - 2 time
and 2 temperature settings (1 setback)
Energy savings up to 33%
Patented pre-programmed schedule simplifies
time and temperature programming
Display
Large, 12-square-inch touchscreen display –
largest in the industry
Blue, lighted display for easier low-light viewing
Larger, easy-to-read character size
Extra-large touch keys for easy operation
Clean, uncluttered touchscreen display provides
easier navigation
Performance
Universal Dual-Powered – choice of
battery-powered or hardwired with
battery back-up
Selectable Energy Management Recovery
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Fast (FA) or slow (SL) heating cycle anticipation
Exclusive “Call for Service” diagnostic indicator
Compressor lockout protection
Millivolt compatible
Electric heat option
Comfort & Convenience
Humidification and dehumidification control
Intuitive menu-driven set-up, programming and
operation, with audio prompt to confirm
touchscreen entries
Permanent program retention during power loss
Indefinite setpoint Hold or
temporary temperature override
Temporary temperature override – can be set
from 15 minutes for Temporary adjustments
up to 7 days for Vacation override
Auto heat/cool changeover option –
automatically switches between heating
and cooling programs
Heating and cooling, heating only or cooling
only configuration (installer selectable)
Setpoint temperature “limited range” capable
Enhanced (variable) touchscreen security
prevents tampering
UV lamp change reminder
Furnace filter change reminder
Humidifier pad change reminder
Maintains room temperature to within +/- 1° F
Room temperature display can be
recalibrated up to +/- 4° F
Dimensions
4.6"H x 5.9"W x 1.2"D
Thermal Specifications
Setpoint Temperature Range:
45° to 99° F (7° to 32° C)
Rated Differential:
Heat 0.6° F; Cool 1.2° F
Operating Ambient Temperature:
32° to 105° F (0° to 41° C)
Operating Humidity Range:
90% non-condensing maximum
Shipping Temperature Range:
-40° to 150° F (-40° to 65° C)
Electrical Specifications
Rating
Battery Power: mV to 30 VAC, NEC Class II,
50/60 HZ or DC
Input-Hardwire: 20 to 30 VAC
1.5 Amps (load per terminal)
2.5 Amps maximum load (all terminals combined)
Standard Systems
Single Stage gas, oil, electric
Single Stage heat pump
Millivolt Systems
Multi-Stage gas, oil electric
Multi-Stage heat pump
Accessories
Indoor Remote Sensor▼
F145-1328
Outdoor Remote Sensor▼
F145-1378
Thermostat Guards
Clear – F29-0198
Metal – F29-0220 (solid base)
F29-0222 (ring base)
Wall Plates
F61-2600 (8.1"W x 5.4H")
F61-2634 (6.5"W x 5"
|
|
|
|
White Rodgers 1F97-1277 Progr./Non-Progr Single-Stage Convention
|
|
White Rodgers 1F97-1277 24V/MILLIVOLT 2 OR 3 WIRE SINGLE STAGE DUAL POWERED DIGITAL PROGRAMMABLE/NON PROGRAMMABLE TOUCHSCREEN THERMOSTAT FOR CONVENTIONAL/HEAT PUMP APPLICATIONS WITH AUTO CHANGEOVER & KEYPAD LOCKOUT 1H-1C 45-99F FEATURES • Large 12-square-inch touchscreen display – largest in the industry. • Extra-large touch keys for easy operation. • Universal Dual-Powered – choice of battery-powered or hardwired with battery back-up. • Meets ENERGY STAR ® specifications.• Meets California Building Code, Title 24. • Universal – choice of 7 day, 5/1/1 day programmable or non-programmable (installer selectable). • Audible feedback. • 1 F95-1277/1F97-1277 include these additional features: – Remote sensing indoor/outdoor. – Programmable fan. – Circulator fan cycling. – Automatic daylight savings option. – Dual-fuel heat pump control (1F95-1277). – Patented Cool Savings. – Enhanced security settings. – 3 wire zone valve. SPECIFICATIONS Electrical Rating Battery Power . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC Input-Hardwire . . . . . . . . . . . . . . . . . . . 20 to 30 VAC Terminal Load . . . . . . . . . . . . . . . . . . . 1 .5 A per terminal, 2.5 A maximum all terminals combined Setpoint Range . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C) Differential (Single Stage) . . . . . . . . . . Heat 0.6°F; Cool 1.2°F Differential (Multi-Stage) . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F Differential (Heat Pump) . . . . . . . . . . . Heat 1.2°F; Cool 1.5°F Operating Ambient . . . . . . . . . . . . . 32 to +105°F (0 to +41°C) Operating Humidity . . . . . . . . . . . . . . . 90% non-condensing max. Shipping Temperature Range . . . . . . . –4 to 150°F (–20 to 65°C) Dimensions . . . . . . . . . . . . . 4 9/16”H x 513/16”W x 13/16”D |
|
|
|
White-Rodgers 1F95-1271 "OBSOLETE Replace with 1F95-1277
|
|
This Thermostat is OBSOLETE ( No Longer Available ) REPLACE WITH 1F95-1277
White-Rodgers 1F95-1271 Thermostat
Single/Multi Stage/Heat Pump Heat/Cool, Programmable or Non-Programmable
Simple and logical installer menu set-up, programming and operation is enhanced by audio prompting that confirms touchscreen entries. Features like variable touchscreen security to prevent tampering, temporary and vacation
overrides, and filter change reminders add convenience. Our +/- 1° temperature accuracy will keep your customers comfortable and protect their HVAC systems. 90 Series Blue is the result of smart, innovative thinking. Install 90 Series
Blue with confidence because it’s exclusively for the professional trade.
FEATURES
Programming;
Universal – installer selectable system
applications (1F95-1271)
Universal – choice of 7 day, 5/1/1 day
programmable or non-programmable (installer
selectable)
4 times and 4 temperature settings per program(2 setbacks) heat and cool, or selectable - 2 timeand 2 temperature settings (1 setback)
Energy savings up to 33%
Patented pre-programmed schedule simplifies
time and temperature programming
Display:
Large, 12-square-inch touchscreen display –
largest in the industry
Blue, lighted display for easier low-light viewing
Larger, easy-to-read character size
Extra-large touch keys for easy operation
Clean, uncluttered touchscreen display provides
easier navigation
Performance:
Universal Dual-Powered – choice of
battery-powered or hardwired with
battery back-up
Selectable Energy Management Recovery
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Fast (FA) or slow (SL) heating cycle anticipation
Easy-to-wire terminal block
B & O terminals
Compressor lockout protection
Millivolt compatible
Electric heat option
Comfort & Convenience:
Intuitive menu-driven set-up, programming and
operation, with audio prompt to confirm
touchscreen entries
Permanent program retention during power loss
Indefinite setpoint Hold or 4-hour temporary
temperature override
Temporary temperature override – can be set
from 15 minutes for Temporary adjustments up to
7 days for Vacation override
Auto heat/cool changeover option –
automatically switches between heating and
cooling programs
Heating and cooling, heating only or cooling only
configuration (installer selectable)
Setpoint temperature “limited range” capable
Enhanced (variable) touchscreen security
prevents tampering
Furnace filter change reminder
Humidifier pad change reminder
Maintains room temperature to within +/- 1°
Room temperature display can be recalibrated up
to +/- 4°
Specifics:
Dimensions
4.6"H x 5.9"W x 1.2"D
Thermal Specifications
Setpoint Temperature Range:
45° to 99° F (7° to 32° C)
Rated Differential:
Heat 0.6° F; Cool 1.2° F
Operating Ambient Temperature:
32° to 105° F (0° to 41° C)
Operating Humidity Range:
90% non-condensing maximum
Shipping Temperature Range:
-4° to 150° F (-20° to 65° C)
Electrical Specifications
Rating
Battery Power: mV to 30 VAC, NEC Class II,
50/60 HZ or DC
Input-Hardwire: 20 to 30 VAC
1.0 Amp (load per terminal)
1.5 Amps maximum load (all terminals
combined)
Standard Systems
Single Stage gas, oil, electric
Single Stage heat pump
Millivolt Systems
Multi-Stage gas, oil electric (1F95-1271)
Multi-Stage heat pump (1F95-1271)
|
|
|
|
White-Rodgers 1F97-1271 OBSOLETE Replace with 1F97-1277
|
|
|
This Thermostat is OBSOLETE ( No Longer Available ) REPLACE WITH 1F97-1277
White-Rodgers 1F97-1271 24V/MILLIVOLT 2-WIRE
SINGLE STAGE DUAL POWERED DIGITAL
PROGRAMMABLE/NON PROGRAMMABLE
TOUCHSCREEN THERMOSTAT FOR
CONVENTIONAL/HEAT PUMP APPLICATIONS
WITH AUTO CHANGEOVER & KEYPAD
LOCKOUT 1H-1C 45-99F
White-Rodgers 1F97-1271 Thermostat
Single Stage Heat/Cool, Programmable or Non-Programmable
Simple and logical installer menu set-up, programming and operation is enhanced by audio
prompting that confirms touchscreen entries. Features like variable touchscreen security to
prevent tampering, temporary and vacation
overrides, and filter change reminders add convenience. Our +/- 1° temperature accuracy
will keep your customers comfortable and protect their HVAC systems. 90 Series Blue is
the result of smart, innovative thinking. Install 90 Series
Blue with confidence because it’s exclusively for the professional trade.
FEATURES
Programming;
Universal – choice of 7 day, 5/1/1 day
programmable or non-programmable (installer
selectable)
4 times and 4 temperature settings per program(2 setbacks) heat and cool, or selectable - 2 timeand 2 temperature settings (1 setback)
Energy savings up to 33%
Patented pre-programmed schedule simplifies
time and temperature programming
Display:
Large, 12-square-inch touchscreen display –
largest in the industry
Blue, lighted display for easier low-light viewing
Larger, easy-to-read character size
Extra-large touch keys for easy operation
Clean, uncluttered touchscreen display provides
easier navigation
Performance:
Universal Dual-Powered – choice of
battery-powered or hardwired with
battery back-up
Selectable Energy Management Recovery
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Fast (FA) or slow (SL) heating cycle anticipation
Easy-to-wire terminal block
B & O terminals
Compressor lockout protection
Millivolt compatible
Electric heat option
Comfort & Convenience:
Intuitive menu-driven set-up, programming and
operation, with audio prompt to confirm
touchscreen entries
Permanent program retention during power loss
Indefinite setpoint Hold or 4-hour temporary
temperature override
Temporary temperature override – can be set
from 15 minutes for Temporary adjustments up to
7 days for Vacation override
Auto heat/cool changeover option –
automatically switches between heating and
cooling programs
Heating and cooling, heating only or cooling only
configuration (installer selectable)
Setpoint temperature “limited range” capable
Enhanced (variable) touchscreen security
prevents tampering
Furnace filter change reminder
Humidifier pad change reminder
Maintains room temperature to within +/- 1°
Room temperature display can be recalibrated up
to +/- 4°
Specifics:
Dimensions
4.6"H x 5.9"W x 1.2"D
Thermal Specifications
Setpoint Temperature Range:
45° to 99° F (7° to 32° C)
Rated Differential:
Heat 0.6° F; Cool 1.2° F
Operating Ambient Temperature:
32° to 105° F (0° to 41° C)
Operating Humidity Range:
90% non-condensing maximum
Shipping Temperature Range:
-4° to 150° F (-20° to 65° C)
Electrical Specifications
Rating
Battery Power: mV to 30 VAC, NEC Class II,
50/60 HZ or DC
Input-Hardwire: 20 to 30 VAC
1.0 Amp (load per terminal)
1.5 Amps maximum load (all terminals
combined)
Standard Systems
Single Stage gas, oil, electric
Single Stage heat pump
Millivolt Systems
|
|
|
|
|
|
White Rodgers 1F95-371 OBSOLETE Replace with 1F95-1277
|
|
| White Rodgers 1F95-371 *** OBSOLETE *** REPLACE WITH 1F95-1277
FEATURES
• 7-Day programming with automatic heat/cool system changeover.
• Fossil fuel or electric heat compatible.
• Large Comfort-ViewTM luminescent display and the industry’s first Lighted Keypad.
• Permanent program retention during power loss.
• Configuration menu allows keypad selection of options – no additional
subbases required.
• Selectable Celsius or Fahrenheit temperature display.
• Programmable blower control and blower delay timings.
• Selectable Energy Management Recovery.
• Built-in system and thermostat diagnostics.
• Up to 4 Digital-signal sensing locations with up to 3 remote indoor sensors plus thermostat. Also displays outdoor temperature with optional outdoor sensor.
Temperature sensing can be averaged or weighted by sensor location.
• Universal model 1F95-377 can be used for multi-stage or heat pump applications.
• Classic White color.
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . .. . 20 to 30 VAC, NEC Class II
Terminal Load . . . . . . . . . . . . . . . . . . . . . . 1.5 A per terminal,
2.5 A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Anticipation, Heating . . . . . . . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . . . . . . . . Adjustable
Rated Differential . . . . . . . . . . . . Heat 0.5 to 1.5°F Cool 0.5 to 2.2°F
Operating Ambient . . . . . . . . . . . . . . . . . 32 to +110°F (0 to +43°C)
Operating Humidity . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . –4 to 149°F (–20 to 65°C)
Dimensions . . . . . . . . . . . . . . . . . . . . . 41/8”H x 67/8”W x 13/8”D
|
| |
|
|
|
|
White Rodgers 1F97-391 Programmable 7 Day,Single-Stage+Humidifie
|
|
White-Rodgers 1F97-391 24V/MILLIVOLT SINGLE STAGE COMFORT-SET III CLOCK STAT W/HUMIDITY SENSING 7 DAY 1H-1C 2 OR 3 WIRE FEATURES • Selectable automatic heat/cool system changeover. • Fossil fuel or electric heat compatible. • Large Comfort-ViewTM luminescent display. • Permanent program retention during power loss. • Configuration menu allows keypad selection of options. • Selectable Celsius or Fahrenheit temperature display. • Programmable blower control and blower delay timings. • Selectable Energy Management Recovery. • Built-in system and thermostat diagnostics. • Digital-signal remote sense capable. • Meets Energy Star specifications – All Progammable Models. • Classic White color.
|
|
|
|
White-Rodgers 1F90-371 OBSOLETE replace with 1F97-1277
|
|
| W-R1F90-371 *** OBSOLETE *** REPLACE WITH 1F97-1277
FEATURES
• Selectable automatic heat/cool system changeover.
• Fossil fuel or electric heat compatible.
• Large Comfort-ViewTM luminescent display.
• Permanent program retention during power loss.
• Configuration menu allows keypad selection of options.
• Selectable Celsius or Fahrenheit temperature display.
• Programmable blower control and blower delay timings.
• Selectable Energy Management Recovery.
• Built-in system and thermostat diagnostics.
• Digital-signal remote sense capable.
• Meets Energy Star specifications – All Progammable Models.
• Classic White color.
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Terminal Load . . . . . . . . . . . . . . . . . . . 0.05 to 1.5 A per terminal,
2.5 A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Anticipation, Heating . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . Adjustable
Rated Differential . . . . . . . . . . . . . . . . Heat 0.5 to 1.5°F
Cool 0.8 to 2.2°F
Operating Ambient . . . . . . . . . . . . . . . 32 to +110°F (0 to +43°C)
Operating Humidity . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . –4 to 149°F (–20 to 65°C)
Dimensions . . . . . . . . . . . . . . . . . . . . . 41/8”H x 67/8”W x 13/8”D
|
| |
|
|
|
|
White-Rodgers 1F93-380 Programmable 7 Day Universal
|
|
Programming
7-Day programming Two pre-programmed time/temperature periods per day (occupied and unoccupied) Vacation Programming button Programmable fan continuous occupied/auto unoccupied Programmable fan on/off delays Separate set-up menus: Installer menu, User menu, Keypad lockout (total/partial) menu
Comfort & Convenience
Large Comfort-View™ display and lighted keypad Permanent program retention — no batteries required Daylight Savings Time quick-change button Air filter change indicator Remote sensing (optional) Outdoor temperature sensing (optional) Ignition control reset Heat pump warm air start
Performance
Multi-stage, heat pump, or single stage up to 2-stage heat*/2-stage cool, with economizer control Auto-changeover EMR (Energy Management Recovery) System and thermostat diagnostics Compressor lockout/auxiliary run time Adjustable differential Telephone access run program (X10 module required) Energy Source Optimizer selects heat pump or fossil fuel system |
|
|
|
|
|
White-Rodgers 1F94-371 OBSOLETE replace with 1F95-1277
|
|
WHite Rodgers 1F94-371 **** OBSOLETE REPLACE WITH 1F95-1277 ****
Programming
7-Day programming
Four pre-programmed time/temperature periods per day
Vacation Programming button
Programmable fan continuous in any period
Programmable fan on/off delays
Separate set-up menus: Installer menu, User menu, Keypad lockout (total/partial) menu
Comfort & Convenience
Large Comfort-View™ display and lighted keypad
Permanent program retention — no batteries required
Daylight Savings Time quick-change button
Air filter change indicator
Remote sensing (optional)
Outdoor temperature sensing (optional)
Ignition control reset (1F95-377, 1F95-371)
Heat pump warm air start (1F95-377, 1F94-371)
Performance
Multi-stage, heat pump, or single stage up to 3-stage heat/2-stage cool
Auto-changeover
EMR (Energy Management Recovery)
System and thermostat diagnostics
Meets ENERGY STAR® specifications
Meets California Building Code, Title 24
Compressor lockout/Auxiliary run time
Adjustable differential
Telephone access run program (X10 module required)
Energy Source Optimizer selects heat pump or
fossil fuel system (1F95-377, 1F94-371) |
|
|
|
White-Rodgers 1F95-377 OBSOLETE replace with 1F95-1277
|
|
This Thermostat is OBSOLETE Replace with 1F95-1277
FEATURES
• 7-Day programming with automatic heat/cool system changeover.
• Fossil fuel or electric heat compatible.
• Large Comfort-ViewTM luminescent display and the industry’s first Lighted Keypad.
• Permanent program retention during power loss.
• Configuration menu allows keypad selection of options – no additional
subbases required.
• Selectable Celsius or Fahrenheit temperature display.
• Programmable blower control and blower delay timings.
• Selectable Energy Management Recovery.
• Built-in system and thermostat diagnostics.
• Up to 4 Digital-signal sensing locations with up to 3 remote indoor sensors plus
thermostat. Also displays outdoor temperature with optional outdoor sensor.
Temperature sensing can be averaged or weighted by sensor location.
• Universal model 1F95-377 can be used for multi-stage or heat pump applications.
• Classic White color.
SPECIFICATIONS
Electrical Rating . . . . . . . . . . . . . . . . . 20 to 30 VAC, NEC Class II
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . 1.5 A per terminal,
2.5 A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Anticipation, Heating . . . . . . . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . . . . . . . . Adjustable
Rated Differential . . . . . . . . . . . Heat 0.5 to 1.5°F Cool 0.5 to 2.2°F
Operating Ambient . . . . . . . . . . . . . . . . . . 32 to +110°F (0 to +43°C)
Operating Humidity . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . –4 to 149°F (–20 to 65°C)
Dimensions . . . . . . . . . . . . . . . . . . . . . 41/8”H x 67/8”W x 13/8”D
Terminals: R, C, G, Y1, Y2, W1, W2, W3/A1, E2/P, E, O, B, L, |
|
|
|
White-Rodgers 1F95-391 Programmable 7 Day,Multi-Stage, Heat Pump
|
|
FEATURES • 7-Day programming with automatic heat/cool system changeover. • Pushbutton Backlight • Temporary Program Override • Indefinite Program Hold • Adjustable Temperature Display • Programmable Fan Control • Programmable Vacation Time/Temperature Operation • Keypad Lockout • Thermostat Startup up After Power Loss • Up to 4 Digital-signal sensing locations with up to 3 remote indoor sensors plus thermostat. Also displays outdoor temperature with optional outdoor sensor. Temperature sensing can be averaged or weighted by sensor location. • Compressor Short Cycle Protection • System and Thermostat Diagnostics • Humidifier Maintenance Indicator • Air Filter Change-Out Indicator • UV Bulb Replacement Indicator • Adjustable Humidity Display • Programmable Automatic Humidity Reduction • Humidifier Control and Monitoring
SPECIFICATIONS Electrical Rating . . . . . . . . . . . . . . 20 to 30 VAC, 50/60Hz with common Terminal Load . .05 to 1.5 A per terminal, 2.5 A maximum all terminals combined Setpoint Range . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C) Rated Differential . . . . . . . . . Heat 0.5 to 1.5°F Cool 0.5 to 2.2°F Operating Ambient . . . . . . . . . . . . . . . . . 32 to 110°F (0 to 43°C) Operating Humidity . . . . . . . . . . . . . . . . . 90% non-condensing max. Shipping Temperature Range . . . . . . . . . . . . . –4 to 149°F (–20 to 65°C) Dimensions . . . . . . . . . . . . . . . . . . . . . 41/8”H x 67/8”W x 13/8”D |
|
|
|
|
|
White-Rodgers 1F96-344 This Thermostat is OBSOLETE
|
|
| White Rodgers 1F96-344 *** is OBSOLETE ***
FEATURES
• Selectable automatic heat/cool system changeover.
• Fossil fuel or electric heat compatible.
• Large Comfort-ViewTM luminescent display.
• Permanent program retention during power loss.
• Configuration menu allows keypad selection of options.
• Selectable Celsius or Fahrenheit temperature display.
• Programmable blower control and blower delay timings.
• Selectable Energy Management Recovery.
• Built-in system and thermostat diagnostics.
• Digital-signal remote sense capable.
• Meets Energy Star specifications – All Progammable Models.
• Classic White color.
SPECIFICATIONS
Electrical Rating . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Terminal Load . . . . . . . . . . . . . . . . . . . 0.05 to 1.5 A per terminal,
2.5 A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Anticipation, Heating . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . Adjustable
Rated Differential . . . . . . .. . . . Heat 0.5 to 1.5°F Cool 0.8 to 2.2°F
Operating Ambient . . . . . . . . . . . . . . . 32 to +110°F (0 to +43°C)
Operating Humidity . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . –4 to 149°F (–20 to 65°C)
Dimensions . . . . . . . . . . . . . . . . . . . . . 41/8”H x 67/8”W x 13/8”D
|
| |
|
|
|
|
White-Rodgers 1F97-371 Obsolete replace with 1F97-1277
|
|
| White Rodgers 1F97-371 ****This thermostat is OBSOLETE REPLACE WITH 1F97-1277 ****
White-Rodgers 1F97-371 24V/MILLIVOLT SINGLE
STAGE COMFORT-SET III CLOCK STAT
W/MULTI VOLTAGE OPTION-7 DAY 1H-1C
2 OR 3 WIRE
FEATURES
• Selectable automatic heat/cool system changeover.
• Fossil fuel or electric heat compatible.
• Large Comfort-ViewTM luminescent display.
• Permanent program retention during power loss.
• Configuration menu allows keypad selection of options.
• Selectable Celsius or Fahrenheit temperature display.
• Programmable blower control and blower delay timings.
• Selectable Energy Management Recovery.
• Built-in system and thermostat diagnostics.
• Digital-signal remote sense capable.
• Meets Energy Star specifications – All Progammable Models.
• Classic White color.
SPECIFICATIONS
Electrical Rating . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Terminal Load . . . . . . . . . . . . . . . . . . . 0.05 to 1.5 A per terminal,
2.5 A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Anticipation, Heating . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . Adjustable
Rated Differential . . . . . . . . . . Heat 0.5 to 1.5°F Cool 0.8 to 2.2°F
Operating Ambient . . . . . . . . . . . . . . . 32 to +110°F (0 to +43°C)
Operating Humidity . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . –4 to 149°F (–20 to 65°C)
Dimensions . . . . . . . . . . . . . . . . . . . . . 41/8”H x 67/8”W x 13/8”D
|
| |
|
|
|
|
White-Rodgers 1F80-224 Programmable 24hr
|
|
White-Rodgers 1F80-224 24V/MILLIVOLT LOW COST HTG/CLG CLOCK STAT-WHITE 24 HR. PROGRAM 1H-1C This White-Rodgers 24-Hour Digital Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control, as well as offer you the flexibility to design heating and cooling programs that fit your needs.
Features: • Simultaneous heat and cool program storage • Preprogrammed temperature control • Four separate time/temperature settings • LCD continuously displays setpoint, and alternately displays time and room temperature • Temperature override until next program period • Manual program override (HOLD temperature) • Temporary HOLD • °F/°C convertibility • Temperature range 45° to 90°F • RC, RH, W, Y, G , O and B terminals • B and O terminals for single stage heat pumps (no auxiliary heat) or damper operation • Program storage in case of power loss • 2 “AA” Energizer® alkaline batteries included |
|
|
|
White-Rodgers 1F80-240 Programmable 5-1-1 Single-Stg Heat Only
|
|
White Rodgers 1F80-240 24V/MILLIVOLT DIGITAL SINGLE STAGE HEAT ONLY PROGRAMMABLE T-STAT 5/1/1 PROGRAM White-Rodgers 5-Day/1-Day/1-Day Digital Thermo-stat uses the technology of a solid-state microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to design a heating program that fits your needs Features: • Separate 5-day (weekday), 1-day (Sat) and 1-day (Sun) pro-gramming with four separate time/temperature periods per day • Preprogrammed temperature control • LCD continuously displays set point, and alternately dis-plays time and room temperature • Heat program storage • Backlit display • Temperature override until next program period • Manual program override (HOLD temperature) • Temporary HOLD • °F/°C convertibility • Temperature range 45° to 90°F • RH, W, and G terminals • Battery powered • 2 "AA" Energizer ® alkaline batteries included |
|
|
|
White-Rodgers 1F80-241 Programmable 5-2 Day, Single-Stage
|
|
White-Rodgers 1F80-241 24V DIGITAL 5/2 DAY SINGLE STAGE PROGRAMMABLE T-STAT 1H-1C 45-90F Improved, the best-selling digital thermostat with new styling and enhanced home comfort features. Building on the proven performance and reliability of the original 1F80 series, we’ve created the new Comfort-Set 80 Series hardwired models… an even better value and a smarter choice for your new installations. Programming Choice of 5/1/1 day programmable (weekday/Sat./Sun.) or non-programmable 4 time and 4 temperature settings per program (heat & cool) Energy savings up to 33% Display 60% larger LCD with improved contrast for easier reading Lighted display for easier low-light viewing Continuous lighted display (optional) Comfort & Convenience Maintains room temperature differential within 1 degree Adjustable room temperature calibration Simple set-up menu to activate optional features Permanent set-up and user program retention during power loss, no batteries needed Performance Selectable EMR (Energy Management Recovery) B&O terminals Meets California Building Code, Title 24 http://www.white-rodgers.com/pdfs/sell_sheets/wr3101-2.pdf |
|
|
|
White-Rodgers 1F80-361 Programmable 5-1-1, Single-Stage
|
|
White-Rodgers 1F80-361 24V/MILLIVOLT SINGLE STAGE PROGRAMMABLE THERMOSTAT 5-1-1 DAY PROGRAM HARDWIRED OR BATTERY POWERED, LIGHTED DISPLAY 1H-1C 45-90F 45% LARGER DISPLAY THAN 1F80-261 FEATURES • Battery powered or hardwired. • Fossil fuel or electric heat compatible. • 60% larger LCD with backlight. • Permanent program retention during power loss. • Configuration menu allows keypad selection of options. • Selectable Celsius or Fahrenheit temperature display. • Selectable Energy Management Recovery • Meets Energy Star specifications • Classic White color.
SPECIFICATIONS Electrical Rating: Dual Power or Battery Power Model . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC Input-Hardwire Model . . . . . . . . . . . . . . . . 20 to 30 VAC Terminal Load . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined Setpoint Temperature Range . . . . . . . . . . . 45 to 90°F (7 to 32°C) Anticipation, Heating . . . . . . . . . . . . . . . . . . Adjustable Anticipation, Cooling . . . . . . . . . . . . . . . . . . Fixed Rated Differential, Heat . . . . . . . . . . . . . . . 0.6° or 1.5°F Rated Differential, Cool . . . . . . . . . . . . . . . . 1.2°F Operating Ambient Temperature Range . . . 32 to 105°F (0 to 44°C) Operating Humidity Range . . . . . . . . . . . . . 0-90% RH noncondensing Shipping Temperature Range . . . . . . . . . . . -4 to +149°F (-20 to +65°C) Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 33/4”H x 6”W x 11/4”D |
|
|
|
|
|
White-Rodgers 1F81-261 Programmable 5-1-1, Multi-Stage
|
|
White-Rodgers 1F81-261 24V MULTI-STAGE DIGITAL PROGRAMMABLE T-STAT 5/1/1 PROGRAM 2H-2C |
|
|
|
White-Rodgers 1F82-261 Programmable 5+1+1, Multi-Stg, Heat Pump
|
|
White-Rodgers 1F82-261 24V MULTI-STAGE HEAT PUMP DIGITAL PROGRAMMABLE T-STAT 2H-1C 5+1+1 PROGRAM FEATURES • 60% larger LCD display with backlight. • Permanent program retention during power loss. • Configuration menu allows keypad selection of options. • Selectable Celsius or Fahrenheit temperature display. • Selectable Energy Management Recovery (1F81-261/1F82-261). • Classic White color. SPECIFICATIONS Electrical Rating . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC, NEC Class II Terminal Load . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5 A maximum all terminals combined Setpoint Range . . . . . . . . . . . . . . . . . . . . . . 45 to 90°F (7 to 32°C) Rated Differential (Multi-Stage) . . . . . . . . . Heat 0.6° or 1.5°F Cool 1.2°F Rated Differential (Heat Pump) . . . . . . . . . Heat & Cool 0.75° or 1.2°F Operating Ambient . . . . . . . . . . . . . . . . . . . 32 to +105°F (0 to +41°C) Operating Humidity . . . . . . . . . . . . . . . . . . 90% non-condensing max. Shipping Temperature Range . . . . . . . . . . –4 to 149°F (–20 to 65°C) Dimensions thermostat . . . . . . . . . . . . . . . 6”H x 33/4”W x 11/4”D |
|
|
|
|
|
|
|
|